DPDT RF Relay for Transfer Bypass of RF Amplifier for reduced power consumption when Telemetry Module power is sufficient (on pad). Rated for 1,000,000 cycles for High Reliability operation, this design uses a Failsafe Actuator with a break before make configuration. The switch exhibits exceptional electrical performance specified from 0.2dBi max for insertion loss and 60 dBi minimum for isolation, and guaranteed over -40°C to +85°C . The assembly requires an operating voltage of +28VDC. External connector includes solder terminals and SMA Female connectors.
Additional Info | |
Name: | DPDT Transfer Bypass Switch |
Description: | Compact High Reliability DPDT RF Relay for Transfer Bypass of RF Amplifier to save power on the launch pad. Only 158 grams and 1.75 x 2.16 x 1.64″. SMA and solder llug connectors. Actuating current of 170mA at 28VDC. |
Features: |
|
Attachments: |